What should I do if the floor heating outlet pipe is not hot? ——Cause analysis and solution guide
As winter approaches, floor heating has become the main heating method for many families. However, if the floor heating outlet pipe is not hot, it will not only affect the heating effect, but may also hide safety hazards. The following is a summary of the issue of non-heating floor heating outlet pipes that has been hotly debated on the Internet in the past 10 days. It combines professional suggestions and user feedback to provide you with structured solutions.
1. Common causes and solutions

| Cause of problem | Performance characteristics | solution |
|---|---|---|
| There is air in the pipe | The water outlet pipe is partially cold, accompanied by the sound of water flowing | Exhaust air through the water distributor exhaust valve until the water flow is stable |
| filter clogged | The water inlet pipe is hot but the water outlet pipe is not hot, the temperature difference is obvious | Close the valve and clean the inner mesh of the Y-type filter |
| Water pump failure | System pressure is insufficient and all pipes are not hot | Check whether the circulation pump is running and replace if necessary |
| Pipe scaling | If it has not been cleaned for many years, the heat dissipation effect will decrease year by year. | Use professional cleaning agents to circulate and flush pipes |
| Improper temperature control settings | The room temperature reaches the standard but the pipe is not hot | Adjust the thermostat to a reasonable temperature (18-22℃ recommended) |
2. Detailed explanation of operating steps
1. Exhaust operation process:
① Close the floor heating main valve
② Use a wrench to open the exhaust valve counterclockwise
③ Keep it on when you hear the "hissing" sound until water comes out
④ Repeat the operation for all loops in sequence
2. Filter cleaning steps:
① Prepare bucket and wrench
② Close the water inlet and return valve
③ Remove the filter and clean the filter screen
④ Open the valve slowly after reinstalling
3. Statistics on high-frequency user problems
| Question type | Proportion | Typical questions |
|---|---|---|
| Exhaust operation questions | 42% | "How long does it take for the temperature to return to normal after exhaust?" |
| Equipment fault diagnosis | 28% | "How to distinguish between a pipe problem and a boiler problem?" |
| Cleaning cycle consultation | 18% | "How often do floor heating pipes need to be professionally cleaned?" |
| Temperature control settings | 12% | "Would lowering the temperature at night save energy?" |
4. Professional maintenance suggestions
1.Annual maintenance:System pressure testing, valve inspections and pipe flushing should be completed before the heating season.
2.Water quality treatment:In areas with hard water, it is recommended to install a water softener to reduce scale formation.
3.Intelligent monitoring:Flow meters and temperature sensors can be installed to monitor the status of each loop in real time.
4.Emergency treatment:If there is a sudden lack of heat in winter, you can try exhausting the air first. If it still doesn't work, you need to contact a professional.
5. Things to note
• Be careful to prevent burns when exhausting, the water temperature may reach above 60℃
• After cleaning the filter, check whether the sealing ring is intact
• It is recommended to keep running at low temperature (above 10℃) when going out for a long time
• When using floor heating in a new house for the first time, the temperature must be gradually raised, and the temperature rise should not exceed 5℃ every day.
Through the above system analysis, most problems of the floor heating outlet pipe not being hot can be solved. If the problem does not improve after trying basic operations, it is recommended to contact a professional floor heating repair service to avoid disassembling core components and causing greater damage.
check the details
check the details