How to deflate the heating vent valve
With the arrival of winter, the frequency of heating use increases, and many families may encounter the problem of not getting hot. One of the common reasons is that there is air blockage in the radiator, which needs to be exhausted through a bleed valve. This article will introduce in detail the operating steps, precautions and FAQs of the heating vent valve to help you quickly solve the problem of the heating not being hot.
1. The function of the heating vent valve

The heating vent valve is a small component in the heating system, mainly used to discharge the air accumulated in the radiator. The presence of air will hinder the flow of hot water, causing the radiator to be partially or completely unheated. Exhaust air through the air release valve to restore the normal working condition of the heater.
2. Operation steps of heating vent valve
| steps | Operating Instructions |
|---|---|
| 1 | Turn off the power to the heating system to ensure safety. |
| 2 | Locate the bleeder valve on the radiator, usually located on the top or side of the radiator. |
| 3 | Prepare a water container and a dry cloth to prevent water from flowing to the ground when deflating. |
| 4 | Use a screwdriver or special key to slowly turn the bleeder valve counterclockwise until you hear a "hissing" exhaust sound. |
| 5 | When the exhaust sound stops and water flows out, immediately close the bleed valve clockwise. |
| 6 | Use a dry cloth to wipe away any water stains around the air release valve to ensure there is no leakage. |
| 7 | Turn the heating system back on and check if the radiator is back to normal operation. |
3. Precautions
1.Safety first: Be sure to turn off the heating system power before operation to avoid the risk of burns or electric shock.
2.Slow operation: The air release valve needs to be rotated slowly to avoid water splashing due to sudden release of pressure.
3.Prevent water leakage: A small amount of water may flow out when deflating. Be sure to catch it with a container to avoid getting the ground wet.
4.Regular inspection: If the radiator frequently needs to be deflated, there may be an air leakage problem in the system. It is recommended to contact a professional for maintenance.
4. Frequently Asked Questions
| question | Answer |
|---|---|
| What should I do if the air release valve cannot be tightened? | It may be that the valve is corroded. You can try dripping a little lubricating oil and tapping it gently before trying again. If it still cannot be tightened, it is recommended to contact a professional. |
| Is the heater still not hot after deflating? | There may be other problems with the heating system, such as a faulty water pump or clogged pipes, which require further inspection. |
| How to deal with leaking air release valve? | If there is slight water leakage, try tightening the valve; if water leakage continues, the valve may be damaged and needs to be replaced. |
5. Summary
The operation of the heating vent valve is not complicated, but it requires attention to safety and details. With the steps and precautions in this article, you can easily solve the problem of your radiator not getting hot. If you encounter a problem that cannot be solved by yourself, it is recommended to contact professional maintenance personnel in time to ensure the normal operation of the heating system.
I hope this article can help you enjoy a warm and comfortable home environment in winter!